If this occurs, try loosening the fuel cap then running the engine again. Battery is connected + restore switch battery has been hold for 3 secs on Inverters. If you try starting the generator without the load connected, itll likely not start. Some of the reasons your generator wont stay running include the following: The safest way to start and use a generator for power generation or other task is to start it, let the roar become smooth then connect the load. The solution to this is simply calling in an expert especially from your generators manufacturer. Sometimes the oil alert system in your engine is actually doing what it should. No carb, but it does have airbox and no openings i can see, On Sat, 6 Feb 2021 16:30:58 +0000, Mike H. My generator is a older model generac generator i think it was built in the 90s it was in storage for about 20 years or so a friend of mine had it and gave it to me . On Friday, September 6, 2013 1:44:01 PM UTC-5, TOM wrote: replying to The Daring Dufas, Dave wrote: That is not what you said in 2013 to the question..WTF?? (View the video above.) You can unclog it with a needle. The following instructions will help you fix the Generator when it doesnt stay running. The issue is quite complicated and must be handled by a professional since it can be difficult to detect. This, in turn, will lead to problems with the engines operations. Remove the wires on the backside of the switch and touch them together. 10 Common Reasons Your Generator Won't Start However, if I wait 24 hours or so between starts, it takes repeated efforts to start again. ), Common Weigh Safe Hitch Problems and Review (Are They Good? Fill the oil tank to remedy this problem. Also, only add fuel to the tank when the generator is cold. it will start and run for about 2-3 seconds then die, but if i hold the starter on is will keep running. A propane generator cannot run on natural gas, and while there are conversion kits available, they are not recommended and may void the manufacturer's warranty. Dave-. Shut it down and let it sit overnight. Before the generator's engine starts, there is no oil pressure. Along with drying out the electrical part of the generator, it keeps fresh fuel in the carburetor. I am presently traveling in California and need to fix the problem ASAP. It does it 4 or 5 times then, You do not have permission to delete messages in this group. Some of the reasons why your generator isn't running smoothly include the following: 1. Because the generator is running fans to cool itself double time, your unit is overworking itself. Thought some rust got in plenum or regulator. The engines failure and inability to continue running is a more serious problem. Depending on the scenario in which the generator shuts itself off, the causes can be different with some quite easy to fix. David Thomas. On Thursday, March 3, 2022 at 9:45:11 AM UTC-5, Sterling wrote: > My generator is a older model generac generator i think it was built in the 90s it was in storage for about 20 years or so a friend of mine had it and gave it to me . Please support our sponsors and let them know you heard about their products on iRV2, "onan 6500 won't start from inside so went to generator compartment pushed start button it would start until I released button then die. Any injury, damage or loss that may result from the improper use of tools, equipment or information contained in this video is the sole responsibility of the viewer and not Steves Small Engine Saloon Inc. As observed in the above solutions, combustion in the combustion chamber only works when an electric current flows in the carburetor and ignites the mixture of fuel and air. But if its a complex one that costs almost the price of a new generator. I do my best to teach you how I easily diagnose problems the fastest, quickest and most efficient way.Whether it be a handheld, two stroke, two cycle engine like chainsaws, weed eaters, string trimmers, grass trimmers, line trimmers, hedge trimmers, strimmers, brush cutters, leaf blowers, or four stroke, four cycle units like lawn mowers, pressure washers, generators, ride on mowers that need parts installed or replaced, Im your guy.Ive been a small engine mechanic for many years so my videos are loaded with tips and tricks that I have learned and want to pass on to you. How to quickly diagnose the low oil shut down on a small engine. Another reason why the generator will not stay running is the lowering of the oil levels. This is mainly caused by high temperatures. I don't believe Generac propane generators have a primer button. Thanks! Too Cold for Your Portable Generator? - Westinghouse Outdoor Power Dear Gary, I have an Onan RV Marquis generator in my Airstream Land Yacht. Every connection should be done keenly. While its rare, a dirty air filter cannot bring sufficient air to the generators engine. The end result of this is the failure of the engine to continue running. If you experience this then the best solution is to call in an expert from your generators manufacturer because these are the folks who made your generator after all. My Generator Wont Stay Running. One thing that can stall or stop your generator is when it has problems getting enough fuel. If running on gasoline turn the generator off by moving the fuel valve to the "off" position and allowing the generator to stall out. For such a case, you will observe the amount of smoke released is less than the usual one. Your generator should run without an issue after this. Key Considerations, Generator Dies Under Load: Likely Cause and How to Fix It. Some fuel components will evaporate over time and what remains is a sticky and thick fuel that can clog up the ports and jets inside the carburetor. This could happen either immediately after you start the generator or after running it for 20 minutes. If there is no current, there will be no ignition and the generator will simply shut itself down. In all the scenarios described above, the carburetor and combustion chamber wont be getting enough fuel and air to enable the generator run properly. Electricity is derived from generators too. These dual fuel generators are most often portable generators that can run on gasoline or propane. -- posted. Check the coolant levels and refill them to curb the overheating aspect. The amount of fuel needed to start the generator is quite low compared to that needed to run it. If it doesnt, it runs the risk of overheating and might be a fire hazard because gasoline is flammable. If its still hot from running, wait till it cools down first. Always make sure that the sensors are in good condition and providing accurate indications before starting the generator. If its a small and rectifiable issue, itll be solved with ease. The propane generator wont stay running. If youve checked the fuel supply and its in good working, check the air filter next. If its higher than the MAX reading, drain some oil from the engine. Dont use water or any other liquid on this element. Generator won't stay running? The more modern the device the harder it is for DIY mechanics to fix the problems. what are the other possible causes? Generatorszone.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide for sites to earn advertising fees by advertising and linking to Amazon.com and other websites. This prevents propane leakage in the event that the zero-pressure regulator should fail. I have become very fond of this product and tend to use it in all of my small engines. Can you offer any other suggestions? You are using an out of date browser. Heres how you test, gain access to and replace a fuel injector in a diesel generator: If you want to try cleaning the fuel injector you can get some cleaner such as theGunk PCD14T Instant Parts Cleaner & Degreaser(link to Amazon) and some generic plastic tubing and follow the steps in this video: A clogged carburetor is one of the likeliest causes of your generator stopping after a few minutes of operation. On the other hand, if the generator shuts itself off when you connect the load, it means that your overloading it. A generator may not stay running because of an overload, insufficient fuel, clogged fuel cap and carburetor amongst other mechanical issues. For the best experience on our site, be sure to turn on Javascript in your browser. If you find out that the air filter is clogged, you can try cleaning it. Most of the problems encountered when using a generator come from misuse. Many modern generators are now designed to shut down if they are overloaded. Contact Us. One of the main issues that could be the source for your Onan generator failing to stay on is the carb. Try loosening the cap to remove clogging. 'G' is usually used for gasoline and 'LP' for propane. i don't know much, just wondering if it could be a dual fuel generator??? Total:1,400 (members:43, guests:1,357), Suburban shuts off after running for hours, Cummins Onan 2500 LP generator will NOT start. If its closed, your generator will not start at all. generator only runs when i hold the start button on - iRV2 During starting, the engine governor will keep the throttle wide open, and this combined with the relatively low RPMs while starting will prevent enough vacuum from being developed to operate the the vacuum switch reliably. A loose spark plug. When troubleshooting ensures the generator is off. In this article, we discuss the various problems people face when operating on the propane generator and the possible solution to them. 1. Generator Starts But Won't Continue To Run - FMCA RV Forums If this correct volume is not met, the generator will automatically shut itself off to prevent damage to the delicate electronics. Make sure to check out the Saloon here tooClick here for my website http://www.stevessmallenginesaloon.com/Click here for my Parts and Tools Store https://www.amazon.com/shop/stevessmallenginesaloon Follow me on Facebook https://www.facebook.com/stevessmallenginesaloon Follow me on Instagram https://www.instagram.com/stevessmallenginesaloon/ Follow me on Twitter https://twitter.com/SteveSaloon Thank you for watching!! [Solved] Why is My Generator Surging (Revving Up and Down)? The manual says that the fuel regulator is rarely the cause of a problem.and to check other possible causes first before replacing it. This is a simple problem of remembering to turn the choke to the OPEN position when the generator is one. To be on the safe side, always check the amount of fuel in the generator before starting it. JavaScript is disabled. If the old gas was left in the small engine for a long period of time, some of the more volatile ingredients may have evaporated and left behind a thicker, stickier substance that could clog up the small jets and ports of the carburetor. Over the past two decades, my family has rehabbed houses and contracted new home builds and Ive learned a lot along the way. Ensure that the generator is installed properly, and sometimes you may need a professional to do the installation for you. This one will require the input of an expert to test each sensor and establish whether its in working condition or not. After these two areas check out or are fixed and you still have the problem, check the air filter and the spark plug. I knew I would eventually find someone on this sight that would help. Leakages can also occur on the fuel system either in a valve or on the body of the pipe. Some situations may mandate a visual inspection and further hands-on testing. And heres how you do just that: The fuel valve regulates the flow of fuel into proper channels. I share my hard-learned lessons so that you can save time and money by not repeating my mistakes. What are you suggesting I look for if I loosen fuel line? If the fuel cap is closed too tightly or the small vent is clogged up, air wont flow into the tank to take up the space left by the used-up fuel. If the generator doesnt shut off by itself like before. American Home Shield provides warranty coverage for your essential home appliances and systems. If we believe that the carburetor could be clogged, wed first use a product called Seafoam to break up any gunk that might be in the tank before trying a different type of cleaner. Improper use. If the spark plug has dirt on the end needed to ignite the air/fuel mixture, itll not produce the spark and the whole combustion process will fail. Function fail. When buying these types of generators, it is good to select the best that will suit all your needs at your home. This is very frustrating, to say the least because your house/outdoor appliances are going to lose power without warning. Ideally, its supposed to be between the MAX and MIN levels on the dipstick. All good. It can lead to your generator stopping after a few minutes, or even engine failure. Checking the whole fuel system will help you identify the cause of the fuel problem and fix it accordingly. One o the reason that makes your generator from running continuously is clogging of the carburetor or bad fuel. You will need to have the generator up and running to turn those screws and adjust the carb. You can replace the fuel valve by following the steps on this video: Fuel injectorscan clog up and block fuel from moving through the combustion system, causing several problems such as having difficulty when starting or when running on load. In some cases, however, the generator may start well but shuts itself off after running for a few minutes. If the fuel cap vent is clogged, air won't be able to enter the tank and a vacuum or "vapor lock" will occur. Carburetor is clogged. what kind of fuel do you smell when you are trying to start and when it is running.??? Find the right portable source of energy for all your crafts, Generator Wont Stay Running: Causes & Quick Fixes. The carburetor on your car might be clogged up, or the fuel youre using may have been bad. If your generator starts but won't keep running, here are two likely issues to check: make sure that it's not overloaded check for fuel or air delivery obstructions A clogged air filter, vapor lock, or dirty carburetor often cause this issue. If you can't run it while stored, consider disconnecting the fuel line and with no load on the generator, running it out of fuel. It produces gas bubbles that can block the fuel delivery. Equipment such as multimeters will be used and most people dont store such in their homes. if its a complex one which costs almost the price of a new generator, youre better off getting a new generator. For this system to work properly, this vent must be unobstructed. In such a case, some parts of the generator will get too hot. Disconnect some electronics from the power then try again. The first is overheating. If you are overloading your generator, there will be leftover soot in that area. How to fix a Honda generator that won't stay running DIY OneForAll 4.44K subscribers Subscribe 177 Share 34K views 4 years ago If your generator will not stay running, this fix may just. When buying a generator for your home or other activity, always calculate the amount of power youll be needing then buy about 1.5 times the output. I have a generac 6500 generator on a 2012 Coachmen Mirada 34BH. This video provides information on how to troubleshoot a generator and the most likely defective parts associated with this problem.Commonly replaced generator parts:Starter AssemblyPull RopeGas TankFuel LineCarburetorFuel FilterAir FilterStatorVoltage RegulatorSpark PlugFind replacement generator parts:https://www.repairclinic.com/Shop-For-Parts/a31/Generator-Parts?TLSID=?1894Visit our Generator Repair Help for more troubleshooting information and repair videos:https://www.repairclinic.com/RepairHelp/Generator-Repair-Help?TLSID=?1894The information provided in this generator troubleshooting video is applicable to all generator brands: Ariens, Bolens, Craftsman, Cub Cadet, Dixon, Echo, Exmark, Green Machine, Homelite, Honda, Huskee, Husqvarna, John Deere, Lawn Boy, MasterCut, Montgomery Wards, MTD, Murray, Poulan, Poulan Pro, Ryobi, Simplicity, Toro, Snapper, Troy-Bilt, Turf King, Weed Eater, Wheel Horse, Worx, Yard Machines, Yard-ManConnect With Us!https://plus.google.com/+repairclinichttps://www.facebook.com/RepairClinichttps://www.twitter.com/RepairClinichttp://pinterest.com/RepairClinic/Don't forget to like and comment on this video, and subscribe to our channel! On older models, you will need to remove the bowl, clean it and then put it back in place. Faulty carburetor. If you notice your exhaust isnt what it usually looks like, make sure you check that out as soon as possible. I want Steves Small Engine Saloon to SAVE YOU TIME, FRUSTRATION AND MOST IMPORTANT, MONEY!If you Google your issue, problem or symptom, you may just see one of my videos pop up! Again, it runs fine once it has been started. (link to Amazon) 17kw Generator Overview Just repair the problem when you find it. Propane powered generator. Videos (Generators Zone Videos & YouTube Channel). It should be a minimum of 60 volts. My Generator Won't Start. - Help Center - Champion Help Center Follow this wire until you locate the green quick connect. But overloading is a common issue with a simple fix so before you start taking it apart, try unplugging some unnecessary devices and see if that solves the problem. replying to Cyndi Jacobs, trader 0 wrote: In article